HeatOS

Your heat pump knows everything.
The controller doesn't write it down.

193 parameters travel along the service bus: refrigerant temperatures, pressures, compressor modulation, every start, every defrost. The display on the wall shows four of them and forgets the rest within fifteen minutes.

HeatOS plugs into that same port and keeps all of it.

193parameters off the bus
152settings you can change
53fault codes explained
5 slive view resolution

live Not a screenshot and not a mock-up. The app is reading a real installation and refreshing every minute, including right now, while you read this.

Check whether HeatOS works with yours

Today we support Panasonic. Not because the others are worse — because every make has to be worked out separately, and we would rather do one properly than five badly.

Panasonic Aquarea, CN-CNT port

Because a heat pump costs as much as a car and tells you nothing

We have worked on heat pumps for years. The most common service call is “something is wrong, the bills came out higher than they should”. And it almost always ends the same way: drive out, plug a laptop into the service port, spend an hour looking at numbers the pump had been recording the whole time and showing to nobody.

That is when it turns out the pump is cycling twelve times an hour because the circuit is restricted. Or that the immersion heater has been running since November because somebody moved one threshold. Or that the cylinder is cooling faster than it should because the circulation pump never stops.

Every one of these is visible in the data from day one. The problem was never that it couldn't be measured — it was that nobody was looking. HeatOS looks every day and says when something stands out.

193 parameters instead of four

That is what actually travels along the service bus. Grouped below exactly the way the app groups them when you choose what to plot.

The display on the wall 4
Aquarea Service Cloud 57
HeatOS 193

Counted, not estimated: the Service Cloud list was transcribed from Panasonic's own panel, ours comes straight from the database of one working installation.

Temperatures

55

Flow, return, heat-exchanger outlet, cylinder, buffer, both zones, room thermostats, pool, solar collector, and the target computed from the heating curve.

Refrigerant circuit

13

Compressor frequency and current, discharge temperature, high and low pressure, evaporator and economiser outlets, expansion valve, power module, both fans, defrost sensor.

Water circuit

9

Flow rate, circulation pump speed and duty, water pressure, three-way and two-way valves, zone mixing valves, second return sensor.

Power and energy

7

Consumption and production separately for heating, hot water and cooling — these are what let the bill be split into “house” and “water”.

States

53

Running, mode, valves, defrost, heaters, sterilisation, anode, bivalent, SG Ready, zone pumps. Drawn as bands below the chart, because a line flicking between nought and one tells you nothing.

Settings

73

Both heating and cooling curves, heater thresholds, bivalent operation, sterilisation, maximum run times, quiet mode — under Panasonic's own names, character for character.

live Flow, return and outdoor temperature · last 24 hours
flow return outdoor

The spikes to 55 °C are cylinder reheats. In the app you can overlay eight parameters on a chart like this and drag a finger across to read every value from a single instant.

The pump does not measure its own electricity. It computes it — and the error has a shape

The figure the pump publishes as "power consumption" comes from no meter. The pump derives it from compressor frequency and a factory table. That does not make it a lie — across a whole day it comes out well. It means you have to know when it is wrong, because the error is not random.

We put one day of operation next to an energy meter with current transformers on the unit's supply — 289 samples, five minutes apart, both figures taken from the same window.

Compressor statePump reportsMeter measures ErrorSamples
Stopped, 0 Hz280 W119 W−58 %13
Modulating, 1–24 Hz447 W516 W+15 %32
Mid load, 25–39 Hz873 W883 W+1 %91
Under load, 40–59 Hz1305 W1278 W−2 %129
Full output, 60 Hz and above2192 W2100 W−4 %24
Whole day, energy total26.52 kWh26.14 kWh −1.4 %289

Plus means the meter sees more than the pump admits. Minus means the pump overstates its own draw. The standstill row rests on thirteen samples and is shown only so it does not look like we picked the convenient bands.

  • +70 W the pump does not know about itself

    At low frequencies the meter sees a steady seventy watts more: the circulation pump, the fan and the controller — fixed loads the factory table leaves out. Against 1500 W that is noise. Against 450 W it is fifteen per cent, and it goes straight into the efficiency figure.

  • At full output the error reverses

    Above sixty hertz the model overstates the compressor by a few per cent. The two errors pull in opposite directions, so across a day they nearly cancel — which is why a single monthly number looks accurate even though it is not accurate inside.

  • The backup heater is not in that figure at all

    The bus reports the heater only as "active" or "inactive". Not one watt. A resistive heater returns heat one for one and draws current like the compressor, so on any day it runs, the pump's model parts company with the bill by exactly what it consumed.

  • Why this matters in practice

    A COP computed from the pump's own data is most optimistic precisely where a well-sized heat pump should spend most of its hours — low modulation. The better the system is set up, the larger the share of hours in which the model misses those seventy watts. So where an energy meter is fitted we take the total from the meter and leave the split between heating, hot water and defrost to the bus: the meter does not know the mode, and the pump does not know the total. Neither source is enough on its own.

One installation, one day, 289 paired readings — Panasonic 9 kW, three-phase meter with current transformers on the unit's supply, on a day with no backup-heater operation. An energy meter is optional equipment and everything works without one; the app then shows the pump's figure and says plainly that it is the pump's figure. Not a study; a measurement at our own site.

Seven things HeatOS finds on its own

Each one is computed from raw readings. There is no model doing the guessing — it is arithmetic on measurements, and you can check it.

  • Short cycling

    Starts per running hour and mean cycle length, derived from the pump's own counter. A compressor starting every ten minutes wears out faster and heats more expensively — and on the wall display it looks exactly like a healthy one.

  • Defrost cycles

    How many, how long, and where the heat came from. If it is drawn from the hot water cylinder, the valve position shows it — and so does the cost of reheating afterwards.

  • Restricted circuit

    The difference between flow and return set against the flow rate. A large delta at a low flow rate means closed loops or a circulation pump running too slowly.

  • Oversizing

    The share of time the compressor spends at its minimum frequency. A pump too large for the building works in short bursts and never reaches the range where it is most efficient.

  • Cylinder standby loss

    Cooling rate in kelvin per hour, converted to watts. On a live installation we measured 0.62 K/h, about 160 W escaping through insulation and circulation — which adds up over a year.

  • Achieved curve against configured

    Whether the pump actually holds what it was told to. A gap means either too little output or a curve set too high — two different faults with one symptom.

  • Sensor drift

    Our own figure from flow and delta against the number the pump reports. A growing difference is the first sign that a sensor has started lying.

The bill stops being a guess

  • Cost in money, not kilowatt-hours

    Day and night tariffs are applied automatically, so a night-time cylinder reheat costs what it actually costs. You also see what share went into which tariff band.

  • The COP you actually get

    Manufacturers quote efficiency at A7/W35. Your pump runs at −3 °C and heats water too. We divide total heat by total electricity rather than averaging ratios — short days with a high ratio would otherwise flatter the result.

  • Hot water broken down by cycle

    Every reheat with its duration and cost, and the cooling rate between them, split into standby and draw-off. You can see what a bath costs and what the insulation is losing.

  • A warning before it becomes a problem

    Controller faults, loss of connection, falling water pressure, a jump in start count. Each of the 53 codes arrives with its cause explained, not just a number to look up.

  • Control when you need it

    Water temperature, heating curve, holiday mode, forced hot water — from your phone, anywhere. The same ranges as the installer menu, because they are the same settings.

What it adds up to

Cycling cut from 12 to 2 starts/hless compressor wear
Immersion heater found and switched offcan be substantial
Heating curve lowered by 3 Karound 9 % of consumption
Hot water circulation on a timeraround 160 W continuous

These are orders of magnitude from service practice, not a promised outcome. What you save depends on the building and on what is actually set wrong — which is precisely why HeatOS measures first and advises second.

Diagnose before you drive out, not after

A call saying “there's no heat” costs you a journey. With the fleet in one view you know whether it's a fault, short cycling, a restricted circuit or a schedule someone switched off — before you get in the van.

The whole fleet on one screen

Connectivity, active faults, installations that stand out. One glance in the morning instead of ten phone calls.

152 settings under the maker's names, 60 of them writable

Transcribed from Aquarea Service Cloud so you never hunt for an equivalent. Fields depending on absent equipment are greyed out, not hidden — you can see they exist and why they don't apply.

Change log

Who, when, from what to what. Changes from the app, from the panel and those made by hand at the pump, in one place. No more arguments about whether the customer “touched anything”.

Chart any parameter

Eight series at once, a second axis per series, a crosshair reading every value at one instant. States as bands below the chart.

Live mode

For the duration of a visit, logging drops to a few seconds, so you can see modulation and the shape of a cycle. It switches itself off afterwards and leaves no clutter in the history.

One plug, fifteen minutes, nothing opened up

1

Module in the service port

It plugs into CN-CNT — the socket the manufacturer provides for a network adapter. Nothing is soldered, the refrigerant circuit stays sealed, no cable is cut. It takes power from the pump, so you don't need a socket.

The unit running on our reference installation is powered over USB; drawing power straight from the service connector is what the current board revision is about. The phone app is not in the App Store or Google Play yet — until it is, the installation is visible in a browser.

2

Connection to your Wi-Fi

The module sends readings over an encrypted connection, one way only, from the house outwards. You open no port on your router — and you shouldn't.

3

Phone and browser

An iPhone app and a web panel. The history stays for good, long after the display on the wall has forgotten it.

What you don't need

Manufacturer's adapterno
Manufacturer's cloud accountno
Open ports on your routerno
Replacing the controllerno
An electrician or live workingno
Touching the refrigerantno

What's in the box

HeatOS modulein its enclosure, ready to plug in
CN-CNT cable5 m, terminated
Fitting instructionswith photographs of the port
Warranty24 months

What we never store can never leak

Payments are handled by a payment provider. Card numbers never pass through our servers or our app — there is nothing of that kind here to steal.

An email address and a postcode are enough to run the service. The postcode is used only to match the weather forecast to your area, because without an outdoor temperature there is no way to judge how the pump is doing. We don't profile you and we don't sell data.

Export the whole history as a file at any time, or erase it from the server — immediately, with no questions asked and no waiting period. Deleted means deleted, not a record flagged inactive.

After you cancel the subscription, the data is erased within 30 days. Not instantly, because an account may be suspended rather than closed — a missed payment, a changed card, a trip away. Wiping the history on the first day of arrears would be an irreversible penalty. Anyone who wants it gone sooner has a button for that and gets it at once.

TransportTLS, outbound only
Key on the phonesystem Keychain
Card datanever stored
Setting rangesenforced on the server
Public viewread-only, no commands
Database and brokerunreachable from the internet

The full description — including a list of what we have not implemented yet — is in Data security. A list of safeguards without a list of gaps would be incomplete.

Seventy-nine ninety-nine for the module and the first year

Module + first year of service
€79.99
One payment. Nothing renews in the background, no card kept on file.
Write to us

We ship to Poland only for now. The terms, the tariff catalogue and the support are Polish, and we would rather say so than take your money and disappoint you. Tell us where you are — we open countries in the order people ask.

What the price covers

  • Module with CN-CNT cable
  • Step-by-step fitting instructions
  • Wi-Fi wizard in the app — no addresses to type
  • Apps for iPhone and Android
  • Browser panel
  • Full measurement history, no time limit
  • Running costs at your own tariff
  • Fault and outage notifications
  • Control from your phone
  • Cycling and loss diagnosis

After the first year

€29.99 a year

We remind you thirty days before it runs out, and again seven days before. We renew nothing on our own and keep no card — if you let it lapse, the service simply drops to the free tier.

Analysis — included in the first year

in the bundle
  • A thermal model of your house, from its own history
  • Seven-day forecast of consumption and cost
  • Written report: what is happening and what follows from it
  • Setting recommendations with the saving worked out
  • Computed on our server — your data does not leave it

Nothing to pay on top in the first year — analysis is part of the €79.99. On renewal it costs €29.99 a year, the same as the service itself.

Without a subscription it keeps working

€0

You keep exactly what the wired controller on the wall shows: running state, mode, outdoor temperature, flow temperature, hot water and circuit 1 with their setpoints, and the fault code if one appears.

History, costs, charts, diagnosis and COP go. The module stays yours and the data waits — renewing at any point brings the full view back.

Installers: pricing is agreed individually, based on how many pumps you monitor. The larger the fleet, the lower the rate per installation — tell us how many you look after.

Before you order

Will this void my warranty?

The module plugs into the service port the manufacturer provides for a wired controller and sends the same commands that controller sends. It does not touch the refrigerant circuit or the electrical installation. Unplugging it leaves no trace.

Which heat pumps are supported?

Panasonic Aquarea with a CN-CNT port: series H, J, K, L and M, monobloc, split and All-in-One. Send a photo of the nameplate if you're unsure and we'll check before you order.

What if the internet or your server goes down?

The pump carries on exactly as before. HeatOS is not part of the control loop — it is a view and a remote. Losing connection means a gap in the chart, not a gap in your heating.

Can I fit it myself?

Yes, if you can remove the indoor unit cover and push a plug into a socket. No live electrical work, nothing involving refrigerant. If you'd rather not, any installer will do it in fifteen minutes.

Could someone take control of my heat pump?

Control requires your account, and every command is range-checked — even a correctly authenticated request outside the safe range is rejected. Hot water cannot be pushed above a safe temperature even from an installer account. The view on this page accepts no commands at all.

How is this different from Aquarea Smart Cloud?

The manufacturer's cloud needs a separate adapter, shows a subset of parameters and doesn't cost anything out at your tariff. It also won't tell you the pump is short cycling or where the defrost heat came from. HeatOS reads the same bus but keeps everything and draws conclusions from it.

Will my pump data go anywhere else?

No. You and the installer you nominate see it. We don't sell it, don't share it for marketing and don't transfer it outside the European Economic Area. The view on this page shows one demonstration installation, with no name, address or town.

The pump measures it anyway. The question is whether anyone is looking.