Temperatures
55Flow, return, heat-exchanger outlet, cylinder, buffer, both zones, room thermostats, pool, solar collector, and the target computed from the heating curve.
193 parameters travel along the service bus: refrigerant temperatures, pressures, compressor modulation, every start, every defrost. The display on the wall shows four of them and forgets the rest within fifteen minutes.
HeatOS plugs into that same port and keeps all of it.
live Not a screenshot and not a mock-up. The app is reading a real installation and refreshing every minute, including right now, while you read this.
Today we support Panasonic. Not because the others are worse — because every make has to be worked out separately, and we would rather do one properly than five badly.
We have worked on heat pumps for years. The most common service call is “something is wrong, the bills came out higher than they should”. And it almost always ends the same way: drive out, plug a laptop into the service port, spend an hour looking at numbers the pump had been recording the whole time and showing to nobody.
That is when it turns out the pump is cycling twelve times an hour because the circuit is restricted. Or that the immersion heater has been running since November because somebody moved one threshold. Or that the cylinder is cooling faster than it should because the circulation pump never stops.
Every one of these is visible in the data from day one. The problem was never that it couldn't be measured — it was that nobody was looking. HeatOS looks every day and says when something stands out.
That is what actually travels along the service bus. Grouped below exactly the way the app groups them when you choose what to plot.
Counted, not estimated: the Service Cloud list was transcribed from Panasonic's own panel, ours comes straight from the database of one working installation.
Flow, return, heat-exchanger outlet, cylinder, buffer, both zones, room thermostats, pool, solar collector, and the target computed from the heating curve.
Compressor frequency and current, discharge temperature, high and low pressure, evaporator and economiser outlets, expansion valve, power module, both fans, defrost sensor.
Flow rate, circulation pump speed and duty, water pressure, three-way and two-way valves, zone mixing valves, second return sensor.
Consumption and production separately for heating, hot water and cooling — these are what let the bill be split into “house” and “water”.
Running, mode, valves, defrost, heaters, sterilisation, anode, bivalent, SG Ready, zone pumps. Drawn as bands below the chart, because a line flicking between nought and one tells you nothing.
Both heating and cooling curves, heater thresholds, bivalent operation, sterilisation, maximum run times, quiet mode — under Panasonic's own names, character for character.
The spikes to 55 °C are cylinder reheats. In the app you can overlay eight parameters on a chart like this and drag a finger across to read every value from a single instant.
The figure the pump publishes as "power consumption" comes from no meter. The pump derives it from compressor frequency and a factory table. That does not make it a lie — across a whole day it comes out well. It means you have to know when it is wrong, because the error is not random.
We put one day of operation next to an energy meter with current transformers on the unit's supply — 289 samples, five minutes apart, both figures taken from the same window.
| Compressor state | Pump reports | Meter measures | Error | Samples |
|---|---|---|---|---|
| Stopped, 0 Hz | 280 W | 119 W | −58 % | 13 |
| Modulating, 1–24 Hz | 447 W | 516 W | +15 % | 32 |
| Mid load, 25–39 Hz | 873 W | 883 W | +1 % | 91 |
| Under load, 40–59 Hz | 1305 W | 1278 W | −2 % | 129 |
| Full output, 60 Hz and above | 2192 W | 2100 W | −4 % | 24 |
| Whole day, energy total | 26.52 kWh | 26.14 kWh | −1.4 % | 289 |
Plus means the meter sees more than the pump admits. Minus means the pump overstates its own draw. The standstill row rests on thirteen samples and is shown only so it does not look like we picked the convenient bands.
At low frequencies the meter sees a steady seventy watts more: the circulation pump, the fan and the controller — fixed loads the factory table leaves out. Against 1500 W that is noise. Against 450 W it is fifteen per cent, and it goes straight into the efficiency figure.
Above sixty hertz the model overstates the compressor by a few per cent. The two errors pull in opposite directions, so across a day they nearly cancel — which is why a single monthly number looks accurate even though it is not accurate inside.
The bus reports the heater only as "active" or "inactive". Not one watt. A resistive heater returns heat one for one and draws current like the compressor, so on any day it runs, the pump's model parts company with the bill by exactly what it consumed.
A COP computed from the pump's own data is most optimistic precisely where a well-sized heat pump should spend most of its hours — low modulation. The better the system is set up, the larger the share of hours in which the model misses those seventy watts. So where an energy meter is fitted we take the total from the meter and leave the split between heating, hot water and defrost to the bus: the meter does not know the mode, and the pump does not know the total. Neither source is enough on its own.
One installation, one day, 289 paired readings — Panasonic 9 kW, three-phase meter with current transformers on the unit's supply, on a day with no backup-heater operation. An energy meter is optional equipment and everything works without one; the app then shows the pump's figure and says plainly that it is the pump's figure. Not a study; a measurement at our own site.
Each one is computed from raw readings. There is no model doing the guessing — it is arithmetic on measurements, and you can check it.
Starts per running hour and mean cycle length, derived from the pump's own counter. A compressor starting every ten minutes wears out faster and heats more expensively — and on the wall display it looks exactly like a healthy one.
How many, how long, and where the heat came from. If it is drawn from the hot water cylinder, the valve position shows it — and so does the cost of reheating afterwards.
The difference between flow and return set against the flow rate. A large delta at a low flow rate means closed loops or a circulation pump running too slowly.
The share of time the compressor spends at its minimum frequency. A pump too large for the building works in short bursts and never reaches the range where it is most efficient.
Cooling rate in kelvin per hour, converted to watts. On a live installation we measured 0.62 K/h, about 160 W escaping through insulation and circulation — which adds up over a year.
Whether the pump actually holds what it was told to. A gap means either too little output or a curve set too high — two different faults with one symptom.
Our own figure from flow and delta against the number the pump reports. A growing difference is the first sign that a sensor has started lying.
Day and night tariffs are applied automatically, so a night-time cylinder reheat costs what it actually costs. You also see what share went into which tariff band.
Manufacturers quote efficiency at A7/W35. Your pump runs at −3 °C and heats water too. We divide total heat by total electricity rather than averaging ratios — short days with a high ratio would otherwise flatter the result.
Every reheat with its duration and cost, and the cooling rate between them, split into standby and draw-off. You can see what a bath costs and what the insulation is losing.
Controller faults, loss of connection, falling water pressure, a jump in start count. Each of the 53 codes arrives with its cause explained, not just a number to look up.
Water temperature, heating curve, holiday mode, forced hot water — from your phone, anywhere. The same ranges as the installer menu, because they are the same settings.
| Cycling cut from 12 to 2 starts/h | less compressor wear |
|---|---|
| Immersion heater found and switched off | can be substantial |
| Heating curve lowered by 3 K | around 9 % of consumption |
| Hot water circulation on a timer | around 160 W continuous |
These are orders of magnitude from service practice, not a promised outcome. What you save depends on the building and on what is actually set wrong — which is precisely why HeatOS measures first and advises second.
A call saying “there's no heat” costs you a journey. With the fleet in one view you know whether it's a fault, short cycling, a restricted circuit or a schedule someone switched off — before you get in the van.
Connectivity, active faults, installations that stand out. One glance in the morning instead of ten phone calls.
Transcribed from Aquarea Service Cloud so you never hunt for an equivalent. Fields depending on absent equipment are greyed out, not hidden — you can see they exist and why they don't apply.
Who, when, from what to what. Changes from the app, from the panel and those made by hand at the pump, in one place. No more arguments about whether the customer “touched anything”.
Eight series at once, a second axis per series, a crosshair reading every value at one instant. States as bands below the chart.
For the duration of a visit, logging drops to a few seconds, so you can see modulation and the shape of a cycle. It switches itself off afterwards and leaves no clutter in the history.
It plugs into CN-CNT — the socket the manufacturer provides for a network adapter. Nothing is soldered, the refrigerant circuit stays sealed, no cable is cut. It takes power from the pump, so you don't need a socket.
The unit running on our reference installation is powered over USB; drawing power straight from the service connector is what the current board revision is about. The phone app is not in the App Store or Google Play yet — until it is, the installation is visible in a browser.
The module sends readings over an encrypted connection, one way only, from the house outwards. You open no port on your router — and you shouldn't.
An iPhone app and a web panel. The history stays for good, long after the display on the wall has forgotten it.
| Manufacturer's adapter | no |
|---|---|
| Manufacturer's cloud account | no |
| Open ports on your router | no |
| Replacing the controller | no |
| An electrician or live working | no |
| Touching the refrigerant | no |
| HeatOS module | in its enclosure, ready to plug in |
|---|---|
| CN-CNT cable | 5 m, terminated |
| Fitting instructions | with photographs of the port |
| Warranty | 24 months |
Payments are handled by a payment provider. Card numbers never pass through our servers or our app — there is nothing of that kind here to steal.
An email address and a postcode are enough to run the service. The postcode is used only to match the weather forecast to your area, because without an outdoor temperature there is no way to judge how the pump is doing. We don't profile you and we don't sell data.
Export the whole history as a file at any time, or erase it from the server — immediately, with no questions asked and no waiting period. Deleted means deleted, not a record flagged inactive.
After you cancel the subscription, the data is erased within 30 days. Not instantly, because an account may be suspended rather than closed — a missed payment, a changed card, a trip away. Wiping the history on the first day of arrears would be an irreversible penalty. Anyone who wants it gone sooner has a button for that and gets it at once.
| Transport | TLS, outbound only |
|---|---|
| Key on the phone | system Keychain |
| Card data | never stored |
| Setting ranges | enforced on the server |
| Public view | read-only, no commands |
| Database and broker | unreachable from the internet |
The full description — including a list of what we have not implemented yet — is in Data security. A list of safeguards without a list of gaps would be incomplete.
We ship to Poland only for now. The terms, the tariff catalogue and the support are Polish, and we would rather say so than take your money and disappoint you. Tell us where you are — we open countries in the order people ask.
We remind you thirty days before it runs out, and again seven days before. We renew nothing on our own and keep no card — if you let it lapse, the service simply drops to the free tier.
Nothing to pay on top in the first year — analysis is part of the €79.99. On renewal it costs €29.99 a year, the same as the service itself.
You keep exactly what the wired controller on the wall shows: running state, mode, outdoor temperature, flow temperature, hot water and circuit 1 with their setpoints, and the fault code if one appears.
History, costs, charts, diagnosis and COP go. The module stays yours and the data waits — renewing at any point brings the full view back.
Installers: pricing is agreed individually, based on how many pumps you monitor. The larger the fleet, the lower the rate per installation — tell us how many you look after.
The module plugs into the service port the manufacturer provides for a wired controller and sends the same commands that controller sends. It does not touch the refrigerant circuit or the electrical installation. Unplugging it leaves no trace.
Panasonic Aquarea with a CN-CNT port: series H, J, K, L and M, monobloc, split and All-in-One. Send a photo of the nameplate if you're unsure and we'll check before you order.
The pump carries on exactly as before. HeatOS is not part of the control loop — it is a view and a remote. Losing connection means a gap in the chart, not a gap in your heating.
Yes, if you can remove the indoor unit cover and push a plug into a socket. No live electrical work, nothing involving refrigerant. If you'd rather not, any installer will do it in fifteen minutes.
Control requires your account, and every command is range-checked — even a correctly authenticated request outside the safe range is rejected. Hot water cannot be pushed above a safe temperature even from an installer account. The view on this page accepts no commands at all.
The manufacturer's cloud needs a separate adapter, shows a subset of parameters and doesn't cost anything out at your tariff. It also won't tell you the pump is short cycling or where the defrost heat came from. HeatOS reads the same bus but keeps everything and draws conclusions from it.
No. You and the installer you nominate see it. We don't sell it, don't share it for marketing and don't transfer it outside the European Economic Area. The view on this page shows one demonstration installation, with no name, address or town.